CALLBACK CALLBACK
  • RU
  • UA
  • EN

Controller NAC-01

The NAC-01 network access controller is designed to control access to residential, industrial or office premises, which are equipped with an electromagnetic or electromechanical lock, a barrier, or a turnstile.
You can create a system of access control and working time recording for one or two access points on the basis of the NAC-01controller. The controller can work in different modes of operation, which should be selected depending on the task that needs to be solved. There are the following possible modes of operation: “door”, “turnstile”, “hotel room”, or their combination in case of using on two points of passage. The following various types of electronic keys can be used as access keys depending on the type of reader that is connected: Touch Memory key chains, Proximity cards of key chains, code keyboards, remote key chains, radio tags, etc.
Readers should be connected to the controller via the 1-Wire (maximum 4 readers) or Wiegand (maximum 2 readers) interface
You should prefer the 1-Wire interface when selecting the type of connection interface.
Programming of the controller should be performed only with the help of “Big Brother” software.

img

Modes of operation

One-Door
Two-Door
Hotel Room

img

Operating parameters

The mounting size of the board is 78 × 100mm
The overall dimensions of the board are 85 × 107mm
Operating temperature range 0 ~ +60 С

img

Network

Ethernet network interface can act as a converter

img

Readers

Keys type Touch Memory
Proximity cards (EM-Marin) and radio keychains
Connecting readers via the interface 1 – Wire or Wiegand

img

Functional features

Door / turnstile control
The function of prohibiting double passage (for each point separately or for two points together)
Internal memory is dynamically allocated between events and keys
Programming up to 4000 keys

SPECIFICATIONS

Parameter Value
Electric
1

Supply voltage

10 – 15 V

2

Rated current (at a supply voltage of 12 V):

relays off, no more

relays included, no more than

 

50 mА

200 mА

3

Maximum switching current of the relay

10 A

4

Maximum switching load of output voltage

24 V

Functional
1

Network interface

Ethernet

2

The number of recorded events in off-line working

up to 32000

3

Number of user keys

up to 4000

4

Number of connected readers:

1-Wire (Touch Memory)

Wiegand

 

4

2

5

Number of outputs (relays)

4

6

Number of inputs

6

7

Real-time clock battery

CR2032 3V

8

Maximum distance to reader by:

1-Wire (Touch Memory)

Wiegand

 

30 m

100 m

Operational
1

Board dimensions

85 x 107 mm

2

Installation board size

 

72 x 100 mm

78 x 100 mm

3

Operating temperature range

0°С ~ + 60°С

EQUIPMENTS

CONNECTION SHEMA

shema